Powerpoint Timeout - 1 Second (2021+) FORScan Code for F-150
Your truck
Add Powerpoint Timeout - 1 Second (2021+) to a worksheet
$9.99
Choose the year, trim, engine, and drivetrain. Nothing is filled in until you pick it.
Sample
Sample worksheet
This is a sample of the layout, not a worksheet for your truck. The paid sheet uses the mods you pick and leaves a blank for each original value. You write any change yourself in FORScan.
Sample rows for a 2021 F-150. These are 2021+ addresses. Auto Start/Stop is not in this sample.
| Module | Address | Your original value | Target value | Notes |
|---|---|---|---|---|
| BCM | 726-39-02 | ____________ | xxx0 xxxx xx-- | Sample layout. 2021+ Bambi Mode. |
| ACM | 727-01-01 | ____________ | xxxx xxxx 0x-- | Sample layout. 2021+ Fake Engine Noise. |
| BCM | 726-63-02 | ____________ | xxx0 xxxx xx-- | Sample layout. 2021+ Double Horn Honk Disable. |
Sample rows only. A purchased worksheet is built from your year, trim, engine, drivetrain, and selected mods. Worksheet purchases are non-refundable except where required by law.
Powerpoint Timeout - 1 Second (2021+) is a lower-risk, convenience-oriented change for 2021–2026 Ford F-150 trucks, applied with FORScan over an OBD-II adapter. Cuts the 12V outlet timeout to one second after key-off. It is fully reversible and typically takes about 5 minutes to write once your worksheet is in hand.
The change touches the Body Control Module (BCM), and your F-Config worksheet lists all 2 as-built code rows with the module, address, and target value. Each row includes a blank for your original value so you can back up before writing changes and roll back later. Outlets die immediately at key-off instead of staying live.
Why F-150 owners use it
Outlets die immediately at key-off instead of staying live
Worksheet rows
2
Modules
1
Estimated time
~5 min
Compatibility
2021-2026
How you'll apply Powerpoint Timeout - 1 Second (2021+)
The DIY process from start to finish — backup-first and, where possible, reversible.
Back up your originals first
Before changing anything, use FORScan to read and record the current value of each of the 2 rows in the Body Control Module (BCM). Your worksheet leaves a blank beside every row for exactly this.
Write the worksheet values
Enter the 2 target rows from your worksheet one at a time. Most owners finish Powerpoint Timeout - 1 Second (2021+) in about 5 minutes with a laptop and a FORScan-compatible OBD-II adapter.
Cycle the ignition and verify
Turn the key off and back on, then confirm the change behaves as expected before moving on. If anything looks off, stop and compare against the originals you recorded.
Roll back anytime
Because Powerpoint Timeout - 1 Second (2021+) is fully reversible, you can put every original value back later and return to stock whenever you want.
Compatible F-150 years
Review year-specific FORScan worksheet context before adding this mod to your build.
Before you write values
Make backups, confirm the adapter can see the truck, and review the FAQ before applying worksheet values.
Printable worksheet preview
Customers get a clean worksheet with original-value blanks, target values, completion checks, and module notes.
| Module | Address | Target value | Notes |
|---|---|---|---|
| BCM | 726-57-01 | xxxx 01xx xx-- | Timeout enabled |
| BCM | 726-57-01 | 0001 xxxx xx-- | Duration in seconds, hex-encoded - 0001 is one second |
Risk and safety notes
Convenience-oriented worksheet item that still requires backups, review, and customer judgment.
Required modules
Powerpoint Timeout - 1 Second (2021+) FORScan FAQ
Is Powerpoint Timeout - 1 Second (2021+) safe to do on my F-150?
It is rated lower risk on F-Config. It is convenience-oriented, but you should still back up your original as-built values before writing anything.
Is Powerpoint Timeout - 1 Second (2021+) reversible?
Yes. This change is fully reversible as long as you record your original as-built values first. Your worksheet leaves a blank for each original value so you can roll back to stock.
Which modules does Powerpoint Timeout - 1 Second (2021+) change?
It writes 2 code rows to the Body Control Module (BCM). Each row is listed in your worksheet with its address and target value.
How long does Powerpoint Timeout - 1 Second (2021+) take with FORScan?
Most owners finish Powerpoint Timeout - 1 Second (2021+) in about 5 minutes once they have the worksheet, a laptop, and a FORScan-compatible OBD-II adapter.
What F-150 years does Powerpoint Timeout - 1 Second (2021+) work on?
Powerpoint Timeout - 1 Second (2021+) applies to 2021–2026 F-150 trucks. Compatibility can still vary by trim, package, and module software version, so confirm against your own as-built data.
Anything to watch out for with Powerpoint Timeout - 1 Second (2021+)?
Both writes are needed: the timeout has to be enabled, and the duration set. This is the opposite of the 2021+ Powerpoint Timeout Disable mod, which uses the same address — do not apply both.
Related SYNC & Media mods
Other FORScan changes in the same category you can add to the same worksheet.
NAV/Video in Motion
Allows navigation and text reading while vehicle is moving
Heated/Cooled Seat Icons on Screen
Shows heated/cooled seat controls on home and climate screen
Heated Steering Wheel Icon on Screen
Shows heated steering wheel control on home and climate screen
Stereo Extended Play
Allows stereo to keep playing after turning off engine
Powerpoint Timeout Disable
Disables power outlet timeout
Stereo Without Accessory Mode (2015)
Allows stereo use without accessory mode on 2015 F-150s